CDR Server Alarm
This alarm is applicable only to Mediant 9000 and Mediant Software.
acCDRServerAlarm
Alarm |
acCDRServerAlarm |
||
---|---|---|---|
OID |
1.3.6.1.4.1.5003.9.10.1.21.2.0.142 |
||
Description |
The alarm is sent when the device fails to send a locally stored CDR file to all the remote CDR (SFTP) servers, which is configured in the SBC CDR Remote Servers table. |
||
Default Severity |
Major |
||
Source Varbind Text |
Board#1 |
||
Event Type |
equipmentAlarm |
||
Probable Cause |
communicationsProtocolError |
||
Severity |
Condition |
Text |
Corrective Action |
Major |
Device failed to send the CDR local storage file to all the configured CDR servers. |
"Device failed to send CDR local storage files to all configured SFTP servers" |
Check the network connectivity to the remote server. |
Cleared |
Device successfully sent the CDR file to at least one of the CDR servers. |
"Files transfer succeeded to one of the CDR servers" |
- |